top of page

Chain Test Results

iwas chain chart.PNG

Test Specifics

Independent testing was performed where 2 chains were run to failure to test the resistance to lengthening

• One was treated with a conventional lubricant, and the other was treated with the same conventional lubricant but with MRP added at 3%

• The red line illustrates the chain with the conventional lubricant

• The blue line illustrates the chain with the conventional lubricant with MRP added at 3%

• The y-axis (vertical) measures the lengthening of the chain by its %

• The x-axis (horizontal) measures the time passed in hours

• The conventional lubricant chain failed at approximately 76 hours and the lengthening of the chain had increased by .325 %

• At 76 hours (time the conventional lubricant chain failed), the lengthening of the MRP empowered chain had only increased by .163%

• The MRP empowered chain failed at approximately 105 hours, and the lengthening of the chain had increased by .300%

Conclusion

• This test concluded a 38% increase in the life of the chain that was treated with Fluidine MRP compared to the conventional lubricant chain

• At the point of failure for the conventional lubricant chain (76 hours), the lengthening on the Fluidine MRP empowered chain was 45.67% less than the lengthening that had occurred on the conventional lubricant chain

bottom of page